Pool compliant screening
Pool Picket 90 laser-cut screen
The most open vertical picket in this range. The gap stays under 100 mm.
One panel, repeated. The module stays the same size on a gate or a wide fence, so the pattern is cropped and repeated rather than stretched.
Pool-compatible design. Designed for use in pool-barrier configurations subject to compliant installation and site conditions. Pool-barrier compliance depends on the applicable NSW requirements, installation, finished ground levels, gate hardware, surrounding structures and site conditions. Final compliance should be confirmed by the appropriate qualified professional or certifier.
- Minimum barrier height used here is 1200 mm above finished ground level.
- Openings stay inside the check used for this pattern: vertical gaps under 100 mm, or perforations of 13 mm or less on a 1.2 m barrier.
- The pattern has no horizontal rails that could be used as a foothold inside the non-climbable zone. AS 1926.1 sets that zone at 900 mm outside the barrier.
- A pool gate still needs to self-close and self-latch. Latch release is generally required at about 1500 mm above ground, or lower only where the standard's shield rules are met.
- States adopt AS 1926.1 through the National Construction Code and their own pool laws. Some still cite the 2012 edition; others are moving to the edition called up by NCC 2022 or 2025. Use the edition your certifier applies.
Shown here at 2400 × 1200 mm. Send the enquiry and the workshop will quote the finished specification.
- Privacy
- Open
- Style
- Modern, Minimal
- Material
- Aluminium / steel, where the design allows
- Applications
- Pool barrier screen, Pool fence addition
- Custom sizing
- Yes, within manufacturing limits
- Custom colour
- Yes
- Frame
- Available
- Installation
- Sydney, subject to site measure
Estimated visual screening in the library is about 46% solid sheet for a typical panel. The live configurator recalculates the pattern balance at your size. It is not a tested privacy rating.
Questions
Can I change the size? Yes. Enter the width and height in the configurator. Panels outside the workshop limits are blocked or sent for review.
How do I get a quote? Send the configuration from the enquiry step. The workshop replies with the quote. A site measure is used when installation or access needs one.
Will this suit a pool? It passes the configured pool-geometry check. The installed barrier still needs a certifier.
Installation
Sydney installation can be requested from the price step. Straightforward single panels inside the metro zone can show an estimated installation figure. Longer runs, retaining walls, balconies and pool fences ask for a site measure instead of inventing a price.